The new standard for storing diesel for refueling vehicles is the ul2085. Arpae ul 2200, utility interactive engine generator. Ul 2085 ul standard for safety protected aboveground. Ul 1238 ul standard for safety control equipment for use with flammable liquid dispensing devices published by ul on july 10, 2015 these requirements cover electrical equipment used for the control and monitoring of flammable liquid and lpgas dispensing devices rated 600 volts or less. Ul 58 covers singlewall and doublewall, bare steel underground tanks. Manufactured as horizontal or vertical, the tank can be cylindrical or rectangular, using carbon or stainless steel. Lorri grainawi director of technical service steel tank institute stispfa api american petroleum institute. Above ground storage tanks ast noxguard storage equipment. An overview of ul underground storage tank standards.
This new standard is the result of industry leaders working with underwriters. Technical requirements for aboveground storage tanks asts. Ul standard 2085, aboveground storage tanks for flammable and combustible liquids, protected type, nonmetallic secondary containment with vehicle impact and projectile resistance. Design standards recognized by nfpa 30 include api 12b, api 12d, api 12f, api 620, api 650, ul 58, ul 80, ul 142, ul 16, ul 1746, ul 2080, ul 2085 and ul 2386. Ul 142 aboveground flammable liquid tanks 1 for more information visit. Ul 2085 acs is one of the few manufacturers to have a ballistic rating on our tanks. Ul 142 vs ul 2080 vs ul 2085 codes and standards general. A second standard that may apply to the use of storage tanks is ul2085. Common components component generator ul 10041, 4, 9 jzgz2 ventilation system fans engine types. The tables in the original standard identified the minimum thickness of the steel, based on the tank diameter and length. General industries and fireguard tanks are ul 2085, ul 142 and f941 labeled and designed for storing flammable and combustible liquids.
The new ul 325 standard is a safety standard for door, drapery, gate, louver, and window operators and systems. Fire test of plastic sprinkler pipe for flame and smoke characteristics. Steel above ground tanks for flammable and combustible liquids author. The fireguard tank is a double wall tank that contains insulation between the inner and outer tank protecting the product from ambient temperature variations and exceeds the ul. Ul2085 aboveground storage tanks fire codes forum icc. Ul 2085 protected aboveground tanks for flammable and combustible liquids. This code has been around for gasoline, it is only new in the way that fire marshalls and local municipalities will require it for diesel fuels. Standard for safety for insulated aboveground tanks for flammable and combustible liquids replaced standard. An electronic document associated with a ul standard for safety or outline of investigation, and issued by ul to propose. However, it offers specific, stricter requirements for storage tanks. We also offer two different types of subscriptions.
Underwriters laboratories ul 2085 standard for insulated secondary containment aboveground tank for flammable liquids. Ul 2085, twohour furnace fire test and two hour simulated pool fire test for insulated and protected tanks. Ul 2085 standard for protected aboveground tanks for. In extending its global public safety mission, ul standards partners with national standards bodies in countries around. Back to standard 2085, edition 2 the cost to purchase this standard varies depending on whether you are ordering a hardcopy, pdf or combination of the two. Ul 2085, protected aboveground tanks for flammable and combustible liquids. This new standard is the result of industry leaders. They are used where a fireprotected tank is needed because of setback limitations or regulatory requirements.
Service shop fabricated aboveground tanks for storage of combustible and flammable liquids. Pdf acrobat reader or word version doc document file size. Ul 2080 standard for fire resistant tanks for flammable. Specifically, these tanks must meet the ul 142 standard in their construction. Specifically, it applies to electric operators for doors, draperies, gates, louvers, windows and other opening and closing appliances rated 600 volts or less. Tank buying guide for storage of flammable and combustible. Ul 142, aboveground steel tanks for flammable and combustible liquids. This article describes ten items one should know about these certified tanks and related code applications. It is also from ul and carries many of the same requirements as ul142.
Projectile resistance ul 2085 section 21 in addition to ul standards, fuel tanks also have to meet all nfpa fire code requirements. I would like for ul 142 to meet and exceed 2080 and 2085, but i think its going to be the other way around. An aboveground, shop fabricated, secondarily contained vessel designed to store flammable and combustible liquids constructed according to underwriters laboratories standard 2085 entitled protected aboveground tanks for flammable and combustible liquids. Ul 2085 is based on ufc appendix iif, and any tank that carries a ul 2085 rating will comply with the ufc appendix. Inspection of shop fabricated asts per the spcc rule. The ul 2085 standard for protected aboveground tanks for flammable and combustible liquids is a construction standard for the tank industry. General industries and fireguard tanks are ul2085, ul142 and f941 labeled and designed. Ansiul 20851999 gost pdf,bs pdf,ansi pdf,api pdf,asme. Manufacturers have taken the concept of the ul142 doublewalled fuel tanks, and achieved compliance to ul 2085 by a combination of rigid design. Ibcs ul 2386 is the fire exposure test standard for ibc ratedapproved for combustible liquid handling. This standard requires a 2hour test at 2000 degrees. Documents sold on the ansi webstore are in electronic adobe acrobat pdf format, however some iso and iec standards are available from amazon in hard copy. Arpae ul 2200, utility interactive engine generator system.
A protected aboveground tanks is a tank that comes with a fire protection rating as part of the unit. Each tank is constructed with a minimum 3 interstice around the inner tank. In addition, swri 9301 allows the fire test to be extended from 2 hours to 4 hours. The tank system shall be listed for ballistics protection in accordance with ul standard 752, levels 5, 6 and 8. Swri 9301 requires the tank used in the impact protection test to be anchored, while ul 2085 requires it to be unanchored. The are several applications, with experience in the industry and technical expertise, transliquid continues to supply storage tanks to your exact specifications.
The first edition of this standard, published in 1925, addressed leakage, buckling from external pressure and venting. Ul 2085 insulated aboveground tanks for flammable and combustible liquid. March 16, 2018 new standard for electricallyoperated pool lifts, ul 603352. Underwriters laboratories is a nonprofit organization dedicated to advancing the ul mission through the discovery and application of scientific knowledge. Ul 2085 ul standard for safety protected aboveground tanks. In addition to ul 2085 and ul 142 standards, fuel tanks also have to meet all nfpa fire code requirements covered in nfpa 30, 37 and 110. It is also from ul and carries many of the same requirements as ul 142. These requirements cover intermediate bulk containers ibcs intended for the storage of flammable and.
Ul 2080 standard for fire resistant tanks for flammable and. With over a century of experience in the development of more than 1,500 standards, ul is an accredited standards developer in the us and canada. The ul 142 standard addressed issues relating to leakage, venting, and the ability of the tank to withstand the development of internal pressures encountered during leak testing. Find the most uptodate version of ul 2085 at engineering360.
January 24, 2018 ansi ul 2201 mitigates carbon monoxide co poisoning for portable generators. Specifying engineers are inclined to use ul2200 as the standard when writing generator set detailed specifications that are being. We conduct rigorous independent research and analyze safety data, convene experts worldwide to address risks, share knowledge through safety education and public outreach initiatives, and. A ul 2085 tank is intended to limit the heat transferred to the primary tank during a fire and to protect the tank from. Our ul2085 has a carbon steel outer shell with 6 of concrete encasing a carbon steel fuel tank. Ul 2085 is a doublewall, fireprotected fuel storage tank which features an inner steel tank with a unique lightweight thermal insulation material that exceeds the 2hour fire rating. A second standard that may apply to the use of storage tanks is ul 2085. Underwriters laboratories ul is an accredited developer of standards for product safety and performance. Insulated aboveground tanks for flammable and combustible liquids. Nationally recognized testing laboratories southwest. The information in this sheet gives details of the designs fuel tank manufacturers are using to meet the dictates of ul 2085, ul142, nfpa 30, 37, and 110, and address the safety factors listed above. Diesel generator set general planned maintenance programs.
A ul 2085 tank is intended to limit the heat transferred to the primary tank during a fire and to protect the tank from an aboveground, shop fabricated, secondarily contained vessel designed to store flammable and combustible liquids constructed according to underwriters laboratories standard 2085 entitled protected. J ul 80 standard for steel tanks for oilburner fuel ulc ordc80. The tank design shall provide a minimum two 2 hour fire rating per ufc appendix standard aiif formerly ufc 797, and ul 2085 protected secondary containment tanks. Ideal for the storing flammable and combustible liquids affected by setback limitations, the ul2085 listed firehoppers unique domed top prevents accumulation of rain, snow, and other debris. Codes recognize the use of ul 142 listed tanks the nfpa 30 flammable and combustible liquids code requires. Later, the standard covered the requirements for steel tank wall thickness, joint construction, fittings and manways. Technical requirements for aboveground storage tanks. Our breadth, established objectivity and proven history mean we are a symbol of trust, enabling us to help provide peace of mind to all. The standard fire protection material shall be lightweight concrete and surround the primary tank. The combination of outer shell and concrete creates a ballistic barrier, a 2hour fire rating, and impact resistance. Small footprint and optional pump equipment packages make the firehopper tanks economical and easy to install. The cost to purchase this standard varies depending on whether you are ordering a hardcopy, pdf or combination of the two. Ul 2085 fire rated tank insulates the product in the tank from ambient temperature variations. Api 620, api 650, ul 58, ul 80, ul 142, ul 16, ul 1746, ul 2080, ul 2085 and ul 2386.
Ul standards encompass uls extensive safety research and scientific expertise. Steel above ground tanks for flammable and combustible liquids 49 cfr 1910. Content provider underwriters laboratories ul add to alert. Can someone explain, in simple terms, the differences between these 3 stamps ul 142, ul 2080, ul 2085. Underwriters laboratories expanded the ul 142, with the seventh edition, to incorporate secondary containment designs, diking and rectangular tank designs. Ul2085 listed protected aboveground tanks for flammable and combustible liquids both inner and outer tanks built per ul142 standards for steel aboveground tanks for flammable and com bustible liquids uniform fire code, 2000 edition article 79 and ufc standard 797 protected tank ul2244, aboveground flammable. Aug 18, 2019 ul 2085 2 hour fire guard and double wall tanks. Double wall ul 2085 fireguard tanks are constructed under this standard. Ul has also developed the ul 2085 standard, insulated secondary containment aboveground tanks for flammable liquids protected tanks. Swri 9301 standard for protected tanks is identical to ul 2085 with 2 exceptions. The tank design shall comply with ul 2085 protected tank standard and shall be tested for ballistics, impact, hose stream, and pool fire ul2085 performance standards. Shop fabricated aboveground tank construction standards. Transliquid is a specialty supplier of superiorquality above ground ul 142 and ul 2085 storage tanks, with a custom approach to each of our customers needs.
445 435 757 1200 567 128 253 537 389 220 1135 1151 1442 722 771 382 50 1178 151 1450 585 908 198 267 866 126 776 619 966 446 942 1171 745 1143 157 1423 541